After building ShipMuDIS, run in the FairShip environment:
Multiple input files are accepted after -f. The output must not already exist. Use --ignore-input-containing STRING (repeatable) to skip matching filenames while searching input directories recursively. Without this option, filenames containing filtered are skipped; supplied patterns replace that default. Explicit input files are not subject to these patterns. -s sets the first muon entry; -n limits the number of input entries (zero processes none; -1 processes all remaining entries).
The filter cut applies independently to each DIS interaction in each material. --filter-option 0 (the default) requires at least two charged daughters with momentum above 1 GeV whose extrapolated positions are within a centred 4 m by 6 m plane: |x| <= 200 cm, |y| <= 300 cm. All daughters start at their DIS vertex. Only crossings in the particle's direction of motion count. Outgoing muons are included by default. Use --exclude-muons to count only charged non-muons. ROOT's PDG database supplies charges, with a nuclear-PDG-code fallback; unknown non-nuclear codes do not count as charged.
Choose another acceptance condition with --filter-option:
Options 1 and 2 require geometry and detector acceptance. Their multiplicities are fixed (two and one respectively); --min-charged applies only to option 0. --exclude-muons applies to all three options. Only intersections along the particle's forward trajectory count, including motion towards decreasing z. These are geometric acceptance tests, not detector-efficiency or interaction models. Daughters are propagated through the field only: there is no energy loss, multiple scattering or absorption in the material they cross. In particular, daughters of MS vertices are not stopped by the remaining shield iron, so the filter keeps more MS interactions than can actually reach the detector; this makes it conservative, and Geant4 removes the rest during replay. The existing custom SetFilter predicate still overrides every mode.
--pythia-decays additionally decays each DIS daughter with Pythia8 before applying the selected filter option. A daughter is replaced recursively only when it moves towards Tr1 and its sampled vacuum-decay vertex is upstream of Tr1; otherwise it remains a filter candidate. Decay products start at their Pythia production vertices. This requires detector acceptance and uses --pythia-decay-seed (default 0, a time-based seed chosen by Pythia8 and wrapped into [1, 900000000] before initialization). The effective seed is logged at info level and can be passed back with --pythia-decay-seed to reproduce the run. Each original daughter's proper lifetime is sampled once; Pythia propagates it to its vacuum decay vertex and samples the lifetimes of its decay products. It models decays in vacuum only, not interactions with detector material. The decayer explicitly enables PDG IDs 211, 321, 130, 310, 3112, 3122, 3222, 3312, 3322, and 3334 (including antiparticles). A decay still contributes daughters only if its sampled vertex is before Tr1.
In C++, call selection.SetFilterOption(1) before or after SetDetectorAcceptance(...). Missing geometry volumes produce an error.
The plane defaults to the global z coordinate of the Tr1 station centre in the imported ROOT geometry, including parent placements. --detector-z overrides it in cm. Like macro/ShipReco.py, the filter loads ShipGeo from the geometry file and calls geomGeant4.addVMCFields(..., withVirtualMC=False) for the SST MainSpecMap; the field maker remains alive throughout filtering. The filename and translation default to ShipGeo.Bfield.fieldMap (relative to VMCWORKDIR) and ShipGeo.Bfield.z. --field-map overrides the filename; explicit paths are resolved relative to the current directory. --field-z supplies an explicit map offset (cm), for example 0 for a map already expressed in global coordinates. Map coordinates are in cm and map file field values in Tesla, as required by ShipBFieldMap.
When the imported geometry contains MuonShieldArea, the filter also loads files/<ShipGeo.shieldName>.root as muonShieldField, with z offset ShipGeo.muShield.Entrance[0] and quadrant symmetry, matching the simulation field setup. --muon-shield-field-map and --muon-shield-field-z override the shield map path and offset (cm). Missing maps or geometry metadata are reported as errors rather than silently omitting shield deflection. Both map files are excluded from recursive input discovery. Geometries without MuonShieldArea continue to support SST-only propagation.
The shield's global z range comes from the MuonShieldArea bounding box, including all parent placements, and is logged at initialization. A nonzero shield map must overlap this range. Nonzero fringe fields outside the iron are retained. Before filtering, a vertex-only scan over the requested -s/-n entries finds the minimum MS vertex z. Earlier vertices in other materials or detector planes lower this limit conservatively. The shield bounds scan skips map layers wholly upstream of this limit; no fixed shield-depth cut is used. Unreadable vertex data falls back to the full map. The original field map and its interpolation remain unchanged. Propagation uses straight lines outside both maps' conservative 3D bounds, jumping to the next ray/bounds intersection, and sums fields where they overlap.
--min-charged sets the minimum number of accepted charged daughters. --no-detector-acceptance explicitly restores multiplicity-only filtering; geometry and field inputs are then optional. Geometry/map files are excluded from recursive event-file discovery.
Only passing interactions are copied, together with their complete daughter lists, cross sections, targets, vertices and times. Muons with no passing DIS interaction are omitted. MC tracks and detector hits are preserved, as are per-material wDIS weights (already normalized during generation). The MuonDIS tree remains compatible with the prepared input schema.
Each material directory contains unweighted validation histograms before the cut and with suffix filtered after the cut. Muon histograms before the cut include zero-DIS entries; filtered muon histograms include only muons with a passing interaction in that material. In detailed mode, muon_vtx_weight_ and muon_vtx_weight_filtered record the per-material wDIS once per input muon in their respective samples, with unit entry weight. Their nominal range is [0, 1000], with fixed bin width and visible flow bins. Momentum fractions use sums of momentum magnitudes; the muon fraction includes all muon daughters. Charged multiplicity histograms always count all charged species, independent of --exclude-muons. Malformed entries are logged and skipped before histogram filling.
Every distribution axis has two additional visible bins of the original width: the first collects values below the nominal lower limit, and the last collects values at or above the nominal upper limit. This applies independently to both axes in 2D histograms, including corner overflow. Values are filled at the flow bin centres, so histogram means include these folded coordinates. Entry counts are unchanged. The labelled filter_counts summary retains its eight bins.
daughter_pdg_grouped_ and daughter_pdg_grouped_filtered group daughters into 11 labelled bins: e+, e-, mu+, mu-, gamma, all neutrinos/antineutrinos, pi+/-, other charged hadrons, pi0, other neutral hadrons, and other particles. Hadron categories use ROOT's meson/baryon classification and charge; nuclei and unrecognized PDG codes are included in the last bin.
The default compact output keeps these distributions before and after selection in each material directory:
Each material also retains filter_counts. The weighted XY efficiency numerators and denominators are retained for every p/pT/material bin. This is 360 histograms with the default material and kinematic bins. --detailed-histograms (or SetDetailedHistograms(true) in C++) additionally books the older redundant projections, raw PDG and momentum-fraction plots, and the per-XY-cell z efficiency numerators/denominators. All files in a merge must use the same histogram mode and binning. Ratios are calculated only from the merged numerator and denominator.
Filter efficiencies are stored as weighted numerator (filter_efficiency_passed_*, filter_efficiency_z_passed_*) and denominator (filter_efficiency_all_*, filter_efficiency_z_all_*) histograms. Sum these inputs across files (and materials, if needed) before dividing passed by all to compute efficiencies. No efficiency ratios or canvases are stored. The output file owns all histograms; closing it releases their memory, including on repeated filtering runs.
New filter outputs contain filter_counts in each material directory, storing processed/selected raw and weighted counts for both muons and DIS interactions. Processed counts cover valid entries, excluding unreadable/malformed entries. Selected muons are counted separately per material: a muon contributes when at least one interaction passes there. Muon weighted counts sum wDIS once per muon; DIS weighted counts sum nDIS * wDIS.
For other selections, supply a C++ predicate (it replaces the default cut):
SetFilter({}) restores the default multiplicity and detector-acceptance cut. The predicate receives all daughters of a single interaction. It can also be declared via ROOT.gInterpreter.Declare when steering from Python.
MagneticTrackPropagator is independent of DIS event data. It takes a ShipBFieldMap*, an optional TGeoManager*, and an optional third ShipBFieldMap* for the muon shield. Positions are in cm, momentum vectors in GeV/c (magnitude and direction together), and charge in units of e. All objects are borrowed: keep them alive and unchanged during propagation. A null field explicitly means zero field for generic transport; the filter requires a supplied map when detector acceptance is enabled.
To include a shield map already loaded and positioned by the caller:
The shield map requires a placed MuonShieldArea volume in the geometry. The NaN detector z keeps the default Tr1 plane; a finite z overrides it. Existing SST-only calls remain supported.
GetVolumeZRange(name) returns the global front/back bounds of a placed volume. IntersectsBox(charge, position, momentum, minimum, maximum) tests whether a forward trajectory enters an axis-aligned box. It stops at the first hit, so a later turning point does not undo a hit. Charged segments use cubic Hermite interpolation and side-face crossings, with the same numerical accuracy limits as the propagator; neutral or entirely field-free tracks use exact ray/box intersection. Charged trajectories that turn in z before any hit remain outside the supported monotonic-z transport model.
Nonzero map layers, neighbouring interpolation cells, map placement, rotations and quadrant symmetry determine conservative global 3D bounding boxes. These boxes can include empty pockets; they never remove weak fields. Transverse misses and field-free gaps use exact linear transport, including possible entry through a side face. Inside the field regions, adaptive RK4 with step doubling follows the Lorentz force; steps are bounded by half the smallest active map grid spacing and a 5 cm maximum path step. No threshold removes weak fringe fields. Grids with nonzero noise throughout their volume consequently require integration throughout that volume.
SetAccuracy(positionTolerance, relativeMomentumTolerance, maxStep) controls the local step comparison tolerances (defaults: 0.001 cm and 1e-6) and maximum step in cm. These are local controls, not a bound on accumulated global error. Cached positions use cubic Hermite interpolation between accepted steps and linear segments; GetTrajectorySize() reports the number of cached points. Queries outside the cached interval return false. Changing accuracy clears the cache; failed trajectory construction also clears it.
Transport includes magnetic bending only, with constant momentum magnitude: no energy loss, scattering, decays or geometry/material navigation. Generic extrapolation can run in either z direction. Tracks with zero momentum, nearly zero pz, a reversal in pz, or failed numerical convergence return false and do not count towards filter acceptance. The cached path represents one monotonic z crossing, not multiple crossings of a curling track. This implementation does not change MuDISProcessor or MuonPath.
SetMuonShieldMinZ(z) restricts the shield bounds scan to the required global z range (cm); GetMuonShieldMinZ() reports the limit. Shield bounds are built lazily on the first charged propagation. A later request extending below the limit automatically expands and rebuilds them, preserving backward propagation and reuse with earlier vertices. The default is the complete map.
Readers call PrepareEntry(tree, entry) before GetEntry(entry). On each file change they bind and type-check branches on that file's tree. All hit vectors, DIS vectors, counts, weights and path-length buffers are cleared before each read. UBT, SBT and SST hit branches are optional and become empty when absent. TD hits, the total and all per-material path lengths, MC tracks and the DIS payload are required (TD hit vectors may be empty). An absent or incompatible required branch fails the read instead of reusing data from an earlier file. Replay rejects such input; filtering/preparation do not process failed reads. Optional branches with an incompatible type also fail the read.